Current post: Selling Agilent DualRemote 350 – We Buy New Used DualRemote 350 (‘s) Top Dollar Paid!

Selling Agilent DualRemote 350 – We Buy New Used DualRemote 350 (‘s) Top Dollar Paid!

If you’re looking to Sell Agilent DualRemote 350 Cable Tester

The DualRemote 350 has the same control buttons on its face as the WireScope 350.

Control Buttons
Power: The Power button turns the unit on and off.
OK: Pressing the OK button does nothing.
Scroll: The Scroll button scrolls through the diagnostic indications.

Indicators
Pair Status Indicators
The pair status indicators turn green or red at the end of a test to show the status of each pair. A red indicator means the associated pair failed the current test.
Warning Indicators
The warning indicators denote conditions that might prevent or impair testing.
Hub/NIC Detected: The Hub/NIC Detected indicator means the DualRemote 350 is connected to a hub/Switch port or NIC port, instead of to a port connected to the WireScope 350. [This function is not yet supported.]
Voltage Warning: The voltage warning indicator means the DualRemote 350 is connected to a line which has a potentially damaging voltage present. This condition usually occurs when attempting to test a line that is connected to a telephone switch.
Calibration Required: The Calibration Required indicator means the DualRemote 350 is not calibrated to the WireSc pe 350. The autotest will not execute until the calibration is performed.
Battery: The battery indicator shows the current state of the DualRemote 350 battery charge.
When an external charger is supplying power to the DualRemote:
• The Battery indicator is steady green when the battery is charging.
• The Battery indicator flashes rapidly green when the battery is fully charged. It may flash slowly if it is cooling between charging cycles.
When no external charger is connected to the DualRemote:
• The Battery indicator is dark when the battery is operating normally.
• The Battery indicator is red when the battery charge is low.
Test Progress and Result Indicators
Progress: The Progress LEDs show approximately how much of the current test is complete, 1/3, 2/3, and complete.
Pass/Fail: The Pass/Fail indicator turns green when the test passes, or red when the test fails.
Diagnostics
The Diagnostics section of the DualRemote 350 front panel provides more detailed information about failing test results.
WS and DR: Indicate at which end of the tested cable the measurement failed.
•WS lights when a failure occurs at the WireScope end of the circuit
• DR lights when a failure occurs at the DualRemote end of the circuit.
•WS and DR both light when failures occur at both ends of the circuit. To determine which failures occurred at which end of the circuit, use the Scroll button.

Buying, Selling, Trading Agilent DualRemote 350

A column of diagnostic indicators shows details about the cause(s) of a
test failure. The failures indicated on the DualRemote 350 are:
Wiremap: Turns red when a fault with the cable connections is detected.
Split Pairs: Turns red when a split pair is detected.
Length/Delay/Skew: Turns red when cable length, signal delay, or skew are outside the passing limits.
NEXT : Turns red when near-end pair-to-pair or power sum faults are detected.
Attenuation: Turns red when attenuation is outside passing limits.
ELFEXT : Turns red when far-end pair-to-pair or power sum faults are detected.
Return Loss: Turns red when the return signal loss exceeds passing limits.
Other: Turns red when any other failing test results occur. If the cable run has multiple test failure causes, the Scroll button scrolls between diagnostic indications. The current selection blinks. The pair indicators and WS or DR indicators associated with the selected failure also blink.
Power
The Power LED turns green when the DualRemote 350 is powered on.

If you’re selling your Agilent DualRemote 350 please fill out form on the right hand side of page.